14 TECHNICAL CHARACTERISTICS
Accuracy
reading value for v > 0,4 m/s
reading value for v < 0,4 m/s
Repeatability
± 0.1% reading value
Velocity range
0.1 ...10 m/s
Temperature
Process temperature:
PP: -10 ºC … 80 ºC
PTFE, PVDF: -20 ºC … 120 ºC
Ebonite: -20 ºC … 90 ºC
Ambient temperature range: -20 ... +60 ºC
Minimum conductivity
20 µS/cm
Power supply
90 ... 265 VAC 50, 60 Hz Power consumption: 5 VA
12 ... 48 VDC Power consumption: 5 W
Analog output
4-20 mA. Active or passive. galvanically isolated from the power supply.
Pulse output
Optoisolated. NPN bipolar transistor. Vmax: 30 VDC. Imax: 30 mA.
Maximum frequency : 5000 Hz
Minimum frequency : 0.01 Hz
Relay outputs
2 relay with potential free contacts.
Contact characteristics:
Maximum voltage : 250 VAC
Maximum current : 8 A
Maximum power : 500 VA
Totalizer
N. of digits: 8 (2 decimals)**
Digit size: 8 mm
Reset: by means of keyboard