3.5 Cable specifications
Model: CERVITRONIC PAR-POS Code 04754502
Construction
Conductor: Annealed electrolytic copper, tinned
As Norm: UNE 21064
Isolator: Polyolefin (PE - Solid)
Composition: By pars
Par shield: Tape Al/Pet + Drain Cu Sn
Cover : 100 % Physical
All over shield: Tape Al/Pet + Drain Cu Sn
Cover: 100 % Physical
Exterior cover: PVC
Colour: Black
Electrical characteristics
Working Voltage: 250 V
Testing Voltage: 1000 V
Electrical resistance: 52,2 /km
Capacity: C* / C** 90-170 pF/m
C* capacity between conductors
C** capacity between one conductor and the rest connected to the shields
Physical characteristics
External diameter: 6,6 mm
Bending radius: 66 mm
Working temperature: -5... +70ºC
Fire risk: Does not propagate flame as per Norm IEC 60332-1 and EN 50265
Section: 0,34 mm2
Weight: 51 kg/km
Cable section
1 PVC cover
2 External shield wire
3 Insulating film
4 Pair 1/2 shield wire
5 PVC insulation
6 Pair 1/2 conductor
7 Aluminium shield