MOUNTING
In order to make the positioning of the insert in the pipe easier, there is a label on one of
its sides with markings indicating the position of the internal pipe diameter for each DN.
Cut this label above the line corresponding to the DN of the pipe, at a distance equal to
the pipe thickness. Peel off the bottom part of the label. Once the insert is placed into its
final position, where the label was cut must coincide with the outer diameter of the pipe.
This ensures that the measuring electrodes penetrate far enough in the area of flow
profile that will allow an accurate measurement.
DN
Sensor
length
Insert
length
C (H)
80
101 93
10 88-s
100 12,5 85,5-s
125 15,5 82,5-s
150 19 79-s
200 25 73-s
250 31 67-s
300 37,5 60,5-s
350 44 54-s
400 50 48-s
500
206 145
62,5 140,5-s
600 75 128-s
700 87,5 115,5-s
800 100 103-s
900 112,5 90,5-s
1000 125 78-s
1200
356 190
150 203-s
1400 175 178-s
1600 200 153-s
1800 225 128-s
2000 250 103-s
Qnom
m
3
/h
90,5
141,3
220,9
318,1
565,5
883,6
1.272.,3
1.731,8
2.261,9
3.534,3
5.089,4
6.927,2
9.047,8
11.451,1
14.137,1
20.357,5
27.708,8
36.191,1
45.804,4
56.548,7