Tecfluid LC40 Series Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
6. TECHNICAL CHARACTERISTICS
Mounting: Vertical / Side mounting.
Fittings: DIN 2501 DN65 PN 16flanges
Others on demand
Minimum liquid density: 0.45 kg/l
Liquid viscosity: maximum 3.000 mPa.s
Repeatability: ±3 mm of the level .
Materials: EN 1.4404 (AISI-316L)
On demand: PVC, PP, PTFE, PVDF
Electrical housing: Metal alloy aluminium
On demand: EN 1.4401 (AISI-316), PP, PTFE
Pressure: PN16 (PN10 for plastic)
On demand: PN40 ... PN400
Liquid temperature: Depends on the following table
(1) The liquid working temperatures are given for an ambient temperature of 20ºC.
Ingress protection IP65
Limit switch characteristics
Complies with 97/23/EC Directive for pressure equipment.
This equipment is considered as being a pressure accessory and NOT a safety accessory
as defined in the 97/23/EC Directive, Article 1, paragraph 2.1.3.
Materials Liquid temperature range
Maximum product
temperature (1)
+ thermal housing
EN 1.4404 (AISI-316L) -50ºC…...150º C 300º C
PVC 0ºC…..50º C -------
PP -20ºC…..90ºC -------
PTFE -20ºC…..150º C -------
PVDF -20ºC.....150º C -------
Switch System Characteristics
Maximum
ambient
temperature
AMM
Snap action switch
C/NO/NC
250 V max.
3 A max.
-25 to +85 ºC
AMD Inductive NAMUR
max.. I > 2.2 mA
min. I < 1.1 mA
-25 to +85 ºC
AMR
Reed switch
C/NO/NC
250 V max.
0.5 A max.
-25 to +85 ºC
AMP
Pneumatic
switch
2 ... 6 bar 0 to +50 ºC
5
Vista de pagina 4
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios