Tecfluid CIP II Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
8. TECHNICAL CHARACTERISTICS
8.1. Power supply
CR-2450 lithium battery
Nominal voltage: 3V
Capacity: 560 mAh
Power consumption: 8 µA
8.2. Totalizer Counter
N. of digits: 7
Size of the digit: 8 mm
Reset: Cannot be reset
8.3. Partial Counter
N. of digits: 5
Size of the digit: 6 mm
Reset: By means of push button or magnet.
8.4. General characteristics
Ingress protection: IP65
Ambient temperature range: 0 … +60 ºC
8.5. Input terminals for CIP II for local mounting
Terminal n.
COVOL Turbine
1 Common Ground
2 Live Live
3 Live
Input characteristics
8.5.1. COVOL
This input is designed for a potential free contact between terminals 1 & 2 of the
connector. Terminal 1 is connected to the common of the instrument. This input
has a 1 M pull-up resistor connected to terminal 1 and to the 3,3 V power supply.
The input has a hysteresis with the switching points situated at about 1 V & 2,1 V.
If an open collector transistor is to be used as the switching element instead of a
COVOL, then the aforementioned parameters must be taken into account.
Due to the presence of a filter to avoid the effects of contact bounce, the maximum
pulse frequency for the COVOL input is 300 Hz.
The minimum input frequency is 0.06 Hz
1 M
2
1
+3.3V
6
Vista de pagina 5
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios